1. Key Specifications
| Key Specifications | Normal Mode |
|---|---|
| Crypto Algorithm | LTC+DOGE+BELLS+JKC+LKY+PEP |
| Hash Rate (GH/s) | 51.5~53.5 ± 5% |
| Power Efficiency @35°C (J/GH) | 149 ± 5% |
| Power Consumption @35°C (W) | 7674~7972 ± 10% |
2. Power Supply Requirements
| Power Supply Requirements | Parameter |
|---|---|
| Input Voltage (VAC) | 380~480, 3~ |
| Maximum Input Current (Amp) | 17 |
| Input Frequency (Hz) | 50/60 |
3. Hardware Configuration
| Hardware Configuration | Parameter |
|---|---|
| Product Dimensions (WDH, mm) | 482*665*86 |
| Packaging Dimensions (WDH, mm) | 567*787*203 |
| Product Net Weight (kg) | 21.0 |
| Gross Weight Including Packaging (kg) | 23.5 |
| Internet Connection | RJ45 Ethernet 10/100M |
4. Environmental Operating Parameters
| Environmental Operating Parameters | Parameter |
|---|---|
| Inlet Liquid Temperature (°C) | 20~60 |
| Operating Humidity (Non-Condensing, RH) | 10%~90% |
| Storage Temperature (°C) | -30~70 |
5. Liquid Operating Parameters
| Liquid Operating Parameters | Parameter |
|---|---|
| Liquid Pressure (bar) | ≤3.5 |
| Liquid Medium | Pure water (or distilled water) + special corrosion inhibitor or antifreeze (select the ratio according to the freezing point) |
| Liquid Flow (L/min) | ≥10.2 L/min for pure water; if antifreeze is used, the flow rate needs to be increased. For example, 30% ethylene glycol aqueous solution requires ≥11 L/min. *Remarks: In normal mode, 10.2 L/min corresponds to an inlet-outlet water temperature difference of approximately 10.5°C. |

Reviews